LEFILTER high-precision interchangeableVelcon I-614C5TB coalescing filter element is a standard 14-inch aviation-grade coalescer cartridge engineered for Parker Velcon filter separator vessels. Fully compliant with EI 1581 6th Edition aviation filtration specifications, this threaded-base coalescer serves as the core first-stage filtration component for hydrocarbon fuel purification. Designed for inside-to-out flow operation, it reliably removes fine solid particulates, free water, and micron-sized emulsified water droplets from jet fuel, diesel, and gasoline. With strictly replicated dimensional parameters, epoxy bonding process, and hydrophilic fiberglass media, our I-614C5TB offers perfect drop-in compatibility with original Velcon housings, ensuring identical field performance and prolonged service cycles for aviation and industrial fuel handling systems.
The Velcon I-614C5TB belongs to the classic I-614 series coalescer lineup, widely recognized in global aviation fueling and bulk fuel terminal industries. Different from compact or heavy-duty oversized filter elements, this 14-inch standard-size coalescer balances stable flow throughput, excellent dirt holding capacity, and reliable water-oil separation efficiency for daily continuous fuel purification. It solves common operational problems such as fuel clouding, residual moisture contamination, and fine particle abrasion, effectively protecting downstream separators, meters, and precision fuel distribution equipment.
The I-614C5TB adopts multi-layer gradient hydrophilic fiberglass media optimized for aviation fuel demulsification. Fuel fluid flows from the inner core to the outer media layer (inside-to-out flow path). The graded fiber structure first traps fine suspended solids, rust debris, and granular contaminants to prevent media surface blinding.
As the fluid penetrates the high-density hydrophilic fiberglass layer, invisible emulsified water droplets are captured and adsorbed by microfibers. Under continuous fluid shear force, scattered micro-droplets collide, merge, and aggregate into large-diameter water beads. Due to gravity difference, the enlarged water droplets separate rapidly from hydrocarbon fuel and settle at the bottom of the filter vessel, achieving thorough dry fuel purification while maintaining stable flow pressure for long-term operation.
1. Standard 14-Inch Threaded Base Configuration
Featuring an accurate threaded base end cap, the I-614C5TB enables fast, stable installation and tight locking inside Velcon filter housings. The threaded structure avoids loose displacement under fluid impact, ensuring sealing stability during long-cycle continuous fuel flow. It perfectly matches original assembly standards with zero installation modification required.
2. Aviation-Grade Hydrophilic Fiberglass Media
Adopting premium multi-density borosilicate fiberglass material, the filter media delivers superior hydrophilic performance and high particle retention accuracy. It efficiently breaks fine fuel emulsions and captures submicron water mist, maintaining consistent demulsification efficiency without fiber shedding, media deformation, or performance degradation.
3. High-Strength Epoxy Integral Bonding
End caps and filter media are bonded with industrial high-strength epoxy resin, forming an integrated anti-leakage structure. This full bonding process eliminates bypass leakage risks and enhances structural rigidity, resisting pressure fluctuation and fluid scouring in 24/7 continuous fuel processing environments.
4. Standard Industrial Dimension Design
OD 6.0 inch, ID 3.5 inch, 14-inch overall length strictly follows Velcon original industry specifications, ensuring full dimensional interchangeability with genuine I-614C5TB cartridges for global standard filter separator vessels.

LEFILTER provides full-range interchangeable Velcon aviation and industrial filter elements, covering mainstream coalescer, separator and pre-filter models for one-stop procurement:
I Series Coalescers: I-614C5TB, I-614C5, I-61481, I-61483, I-61487, I-620C5TB, I-630C5TB and more
SO Series Separators: SO-614C, SO-620C, SO-630C series fuel separator elements
Other Velcon Industrial Filters: Full-size standard and heavy-duty fuel filtration cartridges for aviation depots, refineries and terminal stations
The Velcon I-614C5TB coalescing filter is widely used as the first-stage core filtration element in aviation fuel depots, airport fueling systems, bulk fuel terminal stations, petrochemical refinery fuel processing lines, and industrial light hydrocarbon purification systems. It effectively removes fine solid impurities and emulsified water in fuel, ensuring fuel cleanliness meets aviation-grade standards, protecting downstream precision instruments and fuel delivery equipment, and reducing pipeline corrosion and system maintenance frequency.
Every Velcon I-614C5TB replacement filter undergoes strict bubble point testing and pressure resistance inspection before delivery, fully complying with EI 1581 6th edition aviation standards. Compared with generic alternatives, our I-614C5TB features precise threaded base matching, uniform gradient fiber structure, and stable long-term demulsification performance. It avoids early clogging and incomplete water separation common in low-quality filters, delivering genuine-level filtration stability and longer service life. We support sufficient spot inventory, fast global delivery and customized bulk project solutions.
Q1: What is the main function of Velcon I-614C5TB?
A1: I-614C5TB is a standard aviation coalescing element, mainly used to remove fine solid particles and micron-level emulsified water in jet fuel and diesel, ensuring dry and clean fuel quality for aviation and industrial systems.
Q2: What does the TB suffix stand for?
A2: TB refers to Threaded Base configuration, featuring threaded end cap structure for stable locking installation in standard Velcon filter separator vessels.
Q3: Is this replacement fully compatible with original Velcon housings?
A3: Yes. It completely matches the original size, threaded interface, flow direction and bonding standard, supporting direct drop-in replacement without any modification.
Q4: What industry standard does I-614C5TB comply with?
A4: It strictly meets the EI 1581 6th Edition aviation fuel filtration specification, fully qualified for airport and aviation depot fuel purification.
Q5: What flow direction does this coalescer adopt?
A5: Inside-to-out flow, the standard working flow direction for Velcon I-series coalescing filter separators.
Q6: Do you supply other Velcon I-series and SO-series models?
A6: We provide full lineup of Velcon interchangeable coalescer and separator elements, supporting one-stop batch procurement for all project specifications.
Q7: Can you support sample testing and bulk order customization?
A7: Free sample verification is available. We provide customized packaging, logo printing and exclusive bulk supply solutions for global aviation and industrial fuel projects.
RELATED:
Replacement Velcon I-644C5TB Coalescing Filter Cartridge for Aviation Fuel Water Separation
Replacement SO-644V Velcon separator cartridge filter element for aviation fuel filtration
PCHG Natural Gas Filter Cartridge Model PCHG-312 for Particle Removal
- Compatible Model: Velcon I-614C5TB
- Filter Type: Standard aviation grade coalescing filter element
- Executive Standard: EI 1581 6th Edition Aviation Filtration Standard
- Flow Direction: Inside-to-out
- Overall Length: 14 inches
- Outer Diameter: 6.0 inches
- Inner Diameter: 3.5 inches
- End Cap Type: Threaded base
- Working Temperature: -30℃ ~ +80℃
- Maximum Differential Pressure: 5.2 bar
- Recommended Replacement DP: 1.0 bar
- Filter Media: Gradient hydrophilic fiberglass