Working Principle
Dust-laden gas enters the dust collector, is evenly distributed into the filter chamber through the deflector, then flows downward along the filter bags and passes through the filter bags uniformly. A downward airflow is formed at the bottom of the filter bags, consistent with the direction of dust falling during pulse cleaning, which is beneficial to dust sedimentation and improves the ash cleaning effect.
Performance Advantages
low jet pressure: Generally 0.25~0.35MPa, greatly reducing ash cleaning energy consumption and further extending the service life of filter bags.
pulse control: Provides automatic differential pressure control ash cleaning and manual operation control options.
light weight and small footprint: Light weight, small footprint and low manufacturing cost.
cost-effective: Compared with large reverse jet baghouse dust collectors, under the same air volume, the weight and footprint cost are about 1/3 of the latter.

Application
Metallurgy, casting, mining and chemical industries.
Cement building materials, pharmaceutical and food processing industries.
Industrial processes requiring efficient dust removal and air purification.
Treatment of flue gas pollution and ultra-fine dust in industrial production.
Air purification in dusty industrial environments.
| Model | FLZ-800 | FLZ-1600 | FLZ-2400 | FLZ-3200 | FLZ-4800 |
|---|---|---|---|---|---|
| Number of Units | 1 | 2 | 3 | 4 | 6 |
| Number of Filter Bags | 336 | 672 | 1008 | 1344 | 2016 |
| Filter Bag Specification (mm) | Φ130×6000 | Φ130×6000 | Φ130×6000 | Φ130×6000 | Φ130×6000 |
| Filter Bag Material | Polyester Needle Felt | Polyester Needle Felt | Polyester Needle Felt | Polyester Needle Felt | Polyester Needle Felt |
| Filtration Area (m²) | 800 | 1600 | 2400 | 3200 | 4800 |
| Filtration Wind Speed (m/min) | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Processing Air Volume (m³/h) | 48000 | 96000 | 144000 | 192000 | 240000 |
| Equipment Resistance (Pa) | 800-1500 | 800-1500 | 800-1500 | 800-1500 | 800-1500 |
| Inlet Concentration (g/m³) | 30-100 | 30-100 | 30-100 | 30-100 | 30-100 |
| Dust Removal Efficiency | >99.5% | >99.5% | >99.5% | >99.5% | >99.5% |
| Air Leakage Rate | <3% | <3% | <3% | <3% | <3% |
| Pulse Valve Specification | 3" Submerged Type | 3" Submerged Type | 3" Submerged Type | 3" Submerged Type | 3" Submerged Type |
| Number of Pulse Valves | 24 | 48 | 72 | 96 | 144 |
| Jet Cleaning Time (s) | 0.08 | 0.08 | 0.08 | 0.08 | 0.08 |
| Jet Cleaning Pressure (MPa) | 0.20-0.25 | 0.20-0.25 | 0.20-0.25 | 0.20-0.25 | 0.20-0.25 |
| Air Consumption (m³/Time/Valve) | 0.2-0.25 | 0.2-0.25 | 0.2-0.25 | 0.2-0.25 | 0.2-0.25 |
| Jet Cleaning Interval (s) | 5-20 | 5-20 | 5-20 | 5-20 | 5-20 |
| Screw Motor Power (kW) | 2.2 | 3.5 | 4.0 | 5.5 | 7.5 |
| Equipment Weight (t) | 21 | 36 | 52 | 78 | 118 |