Introduction
The PCHG-536 natural gas filter element is designed to ensure clean, contaminant-free gas in critical natural gas processing and distribution systems. It combines specialized media and rugged construction to meet the rigorous demands of hydrocarbon applications, protecting downstream equipment and optimizing system performance.
Quad-Layer Filtration: Pre-filtration, coalescing, activated carbon adsorption, and final polishing layers remove liquids, solids, and hydrocarbons.
High-Temperature Resistance: Operates reliably in extreme heat up to 450°F (232°C).
Corrosion-Resistant Materials: Constructed with 316 stainless steel and fluoropolymer coatings.
Compact Design: Maximizes filtration area while minimizing space requirements.
Parameter | Value |
---|
Maximum Pressure | 1,500 psi (103 bar) |
Temperature Range | -50°F to 450°F (-46°C to 232°C) |
Gas Flow Rate | Up to 12,000 SCFM |
Liquid Loading | ≤20 g/m³ |
Hydrocarbon Removal | ≥99.5% benzene/toluene |
Natural Gas Processing: Removal of H₂S, CO₂, and mercaptans.
Pipeline Transportation: Protecting compressors and meters from debris.
Power Generation: Gas turbine inlet filtration.
LNG Terminals: Pre-treatment for liquefaction processes.
Specification | Details |
---|
Filter Media | Activated carbon composite + sintered metal |
Filtration Rating | 0.5 microns (solids) |
Liquid Removal | 99.99% droplets ≥0.3 microns |
Dimensions | 36” length × 5” diameter |
Weight | 25 lbs (11.3 kg) |
Connection Type | Flanged (ANSI B16.5 150#) |
The PCHG-536 filter element provides advanced contaminant control for natural gas systems, ensuring compliance with strict industry standards. Its multi-stage design and durable construction make it ideal for high-pressure, high-temperature environments, delivering long-lasting performance and reduced maintenance costs.
Other Model